Checking for non-preferred file/folder path names (may take a long time depending on the number of files/folders) ...

CJCZO -- Soil Moisture, Soil Temperature, Electrical Conductivity, Water Potential -- Jemez 2013 Burned ZOB -- (2010-2021)


Authors:
Owners: This resource does not have an owner who is an active HydroShare user. Contact CUAHSI (help@cuahsi.org) for information on this resource.
Type: Resource
Storage: The size of this resource is 208.1 MB
Created: Nov 19, 2019 at 4:24 a.m.
Last updated: Nov 09, 2021 at 9:33 p.m.
Citation: See how to cite this resource
Content types: Single File Content 
Sharing Status: Public
Views: 1856
Downloads: 663
+1 Votes: Be the first one to 
 this.
Comments: No comments (yet)

Abstract

Soil moisture, temperature and bulk electric conductivity are measured in three various depths, and matric potential is measured at two various depths at six pits located in the Mixed Conifer Zero Order Basin (ZOB), Jemez River Basin, New Mexico. Values are recorded every 10 minutes by Decagon 5TE and MPS-1 sensors.

Subject Keywords

Coverage

Spatial

Coordinate System/Geographic Projection:
WGS 84 EPSG:4326
Coordinate Units:
Decimal degrees
Place/Area Name:
Jemez 2013 Burned ZOB
North Latitude
35.8832°
East Longitude
-106.5341°
South Latitude
35.8820°
West Longitude
-106.5374°

Temporal

Start Date:
End Date:

Content

Additional Metadata

Name Value
czos Catalina-Jemez
czo_id 3739
citation The following acknowledgment should accompany any publication or citation of these data - Logistical support and/or data were provided by the NSF-supported Jemez River Basin and Santa Catalina Mountains Critical Zone Observatory, EAR-0724958. Please contact investigator for detail info and let him/her know how you are planning to use this dataset.
comments Data are provisional and may be subject to revision. In order to determine matric potential, it is necessary to convert the voltage to water potential (WP) using personal calibration or factory calibration equation WP(kPa) = -exp(0.000048*mV^2 - 0.0846*mV + 39.45). Factory calibration is only valid from -10 to -500 kPa. Mixed Conifer Zero Order Basin (ZOB) was renamed to Jemez 2013 Burned ZOB. Data are missing from 6/1/2013 to 7/19/2013 (Pit2, Pit5 and Pit6), to 8/10/2013 (Pit1), to 8/5/2013 (Pit3) and to 8/13/2013(Pit4) because of the Thompson Ridge fire.
keywords soil water, volumetric water content, VWC, bulk electrical conductivity, electrical conductivity, EC, temperature, water potential, matric potential, Valles Caldera, Jemez Mountain, New Mexico
subtitle Jemez 2013 Burned ZOB Soil Moisture, Temperature, Electrical Conductivity and Water Potential
variables Volumetric water content, Temperature, Bulk electrical conductivity, Voltage, Water potential
disciplines Soil Science / Pedology, Hydrology

Credits

Funding Agencies

This resource was created using funding from the following sources:
Agency Name Award Title Award Number
National Science Foundation EAR-0724958
National Science Foundation EAR-1331408
National Science Foundation EAR-1331408
National Science Foundation EAR-1331408

How to Cite

Schaap, M., K. Condon, M. Durcik, M. Losleben (2021). CJCZO -- Soil Moisture, Soil Temperature, Electrical Conductivity, Water Potential -- Jemez 2013 Burned ZOB -- (2010-2021), HydroShare, http://www.hydroshare.org/resource/0348b65d71eb46d38bba7db4cb2826db

This resource is shared under the Creative Commons Attribution CC BY.

http://creativecommons.org/licenses/by/4.0/
CC-BY

Comments

There are currently no comments

New Comment

required