Checking for non-preferred file/folder path names (may take a long time depending on the number of files/folders) ...
This resource contains some files/folders that have non-preferred characters in their name. Show non-conforming files/folders.
This resource contains content types with files that need to be updated to match with metadata changes. Show content type files that need updating.
Authors: |
|
|
---|---|---|
Owners: |
|
This resource does not have an owner who is an active HydroShare user. Contact CUAHSI (help@cuahsi.org) for information on this resource. |
Type: | Resource | |
Storage: | The size of this resource is 345.6 KB | |
Created: | May 05, 2025 at 6:31 p.m. | |
Last updated: | May 06, 2025 at 11:18 p.m. | |
Citation: | See how to cite this resource |
Sharing Status: | Public |
---|---|
Views: | 64 |
Downloads: | 0 |
+1 Votes: | Be the first one to this. |
Comments: | No comments (yet) |
Abstract
Borehole geophysical data (natural gamma, induced electrical conductivity, magnetic susceptibility, fluid temperature, fluid conductivity) from depths of 154.700 to 0.600 feet below top of well casing of dryland critical zone well DCZN-1A, into the Rio Grande Alluvium Aquifer and the Hueco Bolson Aquifer. Borehole logging performed by Bill Smith (Granite Geophysical) and Christian Leach (University of Texas at El Paso). Data is in standard LAS file format. Water level present at a depth of 6.5-7.0 feet below top of casing during measurement.
Subject Keywords
Coverage
Spatial
Temporal
Start Date: | |
---|---|
End Date: |
Content
Additional Metadata
Name | Value |
---|---|
COND | Induced electrical conductivity, units of mS/m |
DEPTH | Depth below top of well casing, in feet. |
MSUS.PPT | Magnetic Susceptibility, in units of PPT |
NGAM.API | Natural gamma measurements from the induced conductivity/magnetic susceptibility tool, in units of API. |
TGam.API | Natural gamma measurements from the fluid temperature and conductivity tool, in units of API. |
TEMP.DegC | Borehole fluid temperature, in units of degrees C. Water level present at a depth of 6.5-7.0 feet below top of casing during measurement. |
FCnd.uS/cm | Borehole fluid electrical conductivity, in units of microSiemens per centimeter. Water level present at a depth of 6.5-7.0 feet below top of casing during measurement. |
Credits
Funding Agencies
This resource was created using funding from the following sources:
Agency Name | Award Title | Award Number |
---|---|---|
U.S. National Science Foundation | #2012475 |
Contributors
People or Organizations that contributed technically, materially, financially, or provided general support for the creation of the resource's content but are not considered authors.
Name | Organization | Address | Phone | Author Identifiers |
---|---|---|---|---|
Bill Smith | Granite Geophysical | |||
Christian Leach | University of Texas at El Paso | TX, US |
How to Cite
This resource is shared under the Creative Commons Attribution CC BY.
http://creativecommons.org/licenses/by/4.0/