Checking for non-preferred file/folder path names (may take a long time depending on the number of files/folders) ...
This resource contains some files/folders that have non-preferred characters in their name. Show non-conforming files/folders.
This resource contains content types with files that need to be updated to match with metadata changes. Show content type files that need updating.
Authors: |
|
|
---|---|---|
Owners: |
|
This resource does not have an owner who is an active HydroShare user. Contact CUAHSI (help@cuahsi.org) for information on this resource. |
Type: | Resource | |
Storage: | The size of this resource is 1.4 KB | |
Created: | Feb 08, 2023 at 7:57 p.m. | |
Last updated: | Feb 08, 2023 at 7:57 p.m. | |
Citation: | See how to cite this resource |
Sharing Status: | Public |
---|---|
Views: | 460 |
Downloads: | 212 |
+1 Votes: | Be the first one to this. |
Comments: | No comments (yet) |
Abstract
A technique based on numerical ground-water flow modeling and unconstrained nonlinear optimization has been developed to provide guidance for protecting municipal ground-water supplies from contamination through capture zone management. The technique involves conventional finite-difference ground-water flow modeling and numerical flowpath/travel time calculation coupled with nonlinear mathematical programming. The objective of the technique is to specify pumping rates for wells in a wellfield such that the configuration of capture zones in relation to existing potential sources of contamination minimizes the risk of contamination while maintaining the required total water output from the wellfield. An important feature of the technique is its ability to incorporate realistic boundary conditions, complicated aquifer configurations, and spatially varying aquifer properties to whatever degree site-specific data are available. Also, the technique is implemented on a personal computer. This approach to ground-water supply protection enhances conventional wellhead protection area delineation because a greater level of protection can be achieved if potential contaminant sources are not even included in capture zones, rather than attempting to reduce the threat of those sources. The effectiveness of the technique was verified through application to a hypothetical ground-water system. Practical aspects were demonstrated with an application in Pekin, Illinois. These efforts demonstrate the utility of an innovative modeling technique in ground-water quality protection.
Subject Keywords
Coverage
Spatial
Content
Additional Metadata
Name | Value |
---|---|
DOI | 10.1111/j.1745-6584.1993.tb01842.x |
Depth | |
Scale | < 10 km² |
Layers | |
Purpose | Scientific investigation (not related to applied problem) |
GroMoPo_ID | 391 |
IsVerified | True |
Model Code | Unknown |
Model Link | https://doi.org/10.1111/j.1745-6584.1993.tb01842.x |
Model Time | |
Model Year | 1993 |
Model Authors | VARLJEN, MD; SHAFER, JM |
Model Country | United States |
Data Available | Report/paper only |
Developer Email | NA |
Dominant Geology | |
Developer Country | USA |
Publication Title | COUPLED SIMULATION-OPTIMIZATION MODELING FOR MUNICIPAL GROUNDWATER SUPPLY PROTECTION |
Original Developer | No |
Additional Information | Hypothetical site |
Integration or Coupling | |
Evaluation or Calibration | Unsure |
Geologic Data Availability | No |
How to Cite
This resource is shared under the Creative Commons Attribution CC BY.
http://creativecommons.org/licenses/by/4.0/
Comments
There are currently no comments
New Comment