Checking for non-preferred file/folder path names (may take a long time depending on the number of files/folders) ...

CJCZO -- Soil Moisture, Soil Temperature, Electrical Conductivity, Water Potential -- Jemez 2011 Burned ZOB -- (2011-2021)


Authors:
Owners: This resource does not have an owner who is an active HydroShare user. Contact CUAHSI (help@cuahsi.org) for information on this resource.
Type: Resource
Storage: The size of this resource is 234.8 MB
Created: Nov 19, 2019 at 4:38 a.m.
Last updated: Nov 08, 2021 at 11:06 p.m.
Citation: See how to cite this resource
Content types: Single File Content 
Sharing Status: Public
Views: 1934
Downloads: 564
+1 Votes: Be the first one to 
 this.
Comments: No comments (yet)

Abstract

Soil moisture, temperature, bulk electric conductivity are measured in three various depths and water potential in two various depths at six pits located in the Jemez 2011 Burned Zero Order Basin (ZOB), Jemez River Basin, New Mexico. Values are recorded every 10 minutes by Decagon 5TE and MPS-2 sensors.

Subject Keywords

Coverage

Spatial

Coordinate System/Geographic Projection:
WGS 84 EPSG:4326
Coordinate Units:
Decimal degrees
Place/Area Name:
Jemez 2011 Burned ZOB
North Latitude
35.8506°
East Longitude
-106.4493°
South Latitude
35.8478°
West Longitude
-106.4509°

Temporal

Start Date:
End Date:

Content

Additional Metadata

Name Value
czos Catalina-Jemez
czo_id 3790
citation The following acknowledgment should accompany any publication or citation of these data - Logistical support and/or data were provided by the NSF-supported Jemez River Basin and Santa Catalina Mountains Critical Zone Observatory, EAR-0724958. Please contact investigator for detail info and let him/her know how you are planning to use this dataset.
comments Data are provisional and may be subject to revision. In order to determine matric potential, it is necessary to convert the voltage to water potential (WP) using personal calibration or factory calibration equation WP(kPa) = -exp(0.000048*mV^2 - 0.0846*mV + 39.45). Factory calibration is only valid from -10 to -500 kPa.
keywords soil water, volumetric water content, VWC, bulk electrical conductivity, electrical conductivity, EC, temperature, Water potential, Valles Caldera, Jemez Mountain, New Mexico
subtitle Jemez 2011 Burned ZOB Soil Moisture, Temperature, Electrical Conductivity and Water Potential
variables Volumetric water content, Temperature, Bulk electrical conductivity, Voltage, Water potential
Field Area Jemez 2011 Burned ZOB http://criticalzone.org/catalina-jemez/infrastructure/field-area/jemez-2011-burned-zob/
disciplines Hydrology, Soil Science / Pedology

Credits

Funding Agencies

This resource was created using funding from the following sources:
Agency Name Award Title Award Number
National Science Foundation EAR-0724958
National Science Foundation EAR-1331408

How to Cite

Schaap, M., K. Condon, M. Durcik, M. Losleben (2021). CJCZO -- Soil Moisture, Soil Temperature, Electrical Conductivity, Water Potential -- Jemez 2011 Burned ZOB -- (2011-2021), HydroShare, http://www.hydroshare.org/resource/3c88818b8f014e09afcffdc4089b0ffb

This resource is shared under the Creative Commons Attribution CC BY.

http://creativecommons.org/licenses/by/4.0/
CC-BY

Comments

There are currently no comments

New Comment

required