Checking for non-preferred file/folder path names (may take a long time depending on the number of files/folders) ...

GroMoPo Metadata for Lower Var Valley model


Authors:
Owners: This resource does not have an owner who is an active HydroShare user. Contact CUAHSI (help@cuahsi.org) for information on this resource.
Type: Resource
Storage: The size of this resource is 3.3 KB
Created: Apr 13, 2023 at 1:39 p.m.
Last updated: Apr 13, 2023 at 1:39 p.m.
Citation: See how to cite this resource
Sharing Status: Public
Views: 484
Downloads: 163
+1 Votes: Be the first one to 
 this.
Comments: No comments (yet)

Abstract

Integrated hydrodynamic modelling is an efficient approach for making semi-quantitative scenarios reliable enough for groundwater management, provided that the numerical simulations are from a validated model. The model set-up, however, involves many inputs due to the complexity of both the hydrological system and the land use. The case study of a Mediterranean alluvial unconfined aquifer in the lower Var valley (Southern France) is useful to test a method to estimate lacking data on water abstraction by small farms in urban context. With this estimation of the undocumented pumping volumes, and after calibration of the exchange parameters of the stream-aquifer system with the help of a river model, the groundwater flow model shows a high goodness of fit with the measured potentiometric levels. The consistency between simulated results and real behaviour of the system, with regard to the observed effects of lowering weirs and previously published hydrochemistry data, confirms reliability of the groundwater flow model. On the other hand, accuracy of the transport model output may be influenced by many parameters, many of which are not derived from field measurements. In this case study, for which river-aquifer feeding is the main control, the partition coefficient between direct recharge and runoff does not show a significant effect on the transport model output, and therefore, uncertainty of the hydrological terms such as evapotranspiration and runoff is not a first-rank issue to the pollution propagation. The simulation of pollution scenarios with the model returns expected pessimistic outputs, with regard to hazard management. The model is now ready to be used in a decision support system by the local water supply managers.

Subject Keywords

Coverage

Spatial

Coordinate System/Geographic Projection:
WGS 84 EPSG:4326
Coordinate Units:
Decimal degrees
Place/Area Name:
France
North Latitude
43.8693°
East Longitude
7.2318°
South Latitude
43.6480°
West Longitude
7.1643°

Content

Additional Metadata

Name Value
DOI 10.1007/s11356-018-1437-0
Depth N/A
Scale 11 - 101 km²
Layers 1
Purpose Groundwater resources, Groundwater contamination
GroMoPo_ID 2003
IsVerified True
Model Code Feflow
Model Link https://doi.org/10.1007/s11356-018-1437-0
Model Time 2009-2013
Model Year 2019
Creator Email kcompare@fsu.edu
Model Country France
Data Available Report/paper only
Developer Email olivier.fouche-grobla@lecnam.net
Dominant Geology Unconsolidated sediments
Developer Country France
Publication Title Water planning in a mixed land use Mediterranean area: point-source abstraction and pollution scenarios by a numerical model of varying stream-aquifer regime
Original Developer No
Additional Information N/A
Integration or Coupling None of the above
Evaluation or Calibration Dynamic water levels
Geologic Data Availability No

How to Cite

GroMoPo, K. Compare (2023). GroMoPo Metadata for Lower Var Valley model, HydroShare, http://www.hydroshare.org/resource/6667cfaadf06446e935fb2bd3931a6a3

This resource is shared under the Creative Commons Attribution CC BY.

http://creativecommons.org/licenses/by/4.0/
CC-BY

Comments

There are currently no comments

New Comment

required