Checking for non-preferred file/folder path names (may take a long time depending on the number of files/folders) ...
This resource contains some files/folders that have non-preferred characters in their name. Show non-conforming files/folders.
This resource contains content types with files that need to be updated to match with metadata changes. Show content type files that need updating.
Authors: |
|
|
---|---|---|
Owners: |
|
This resource does not have an owner who is an active HydroShare user. Contact CUAHSI (help@cuahsi.org) for information on this resource. |
Type: | Resource | |
Storage: | The size of this resource is 24.1 KB | |
Created: | Nov 19, 2019 at 4:55 a.m. | |
Last updated: | Feb 11, 2021 at 6:59 p.m. | |
Citation: | See how to cite this resource | |
Content types: | Single File Content |
Sharing Status: | Public |
---|---|
Views: | 2074 |
Downloads: | 29 |
+1 Votes: | Be the first one to this. |
Comments: | No comments (yet) |
Abstract
Manual discharge measurements at the Boulder Creek CZO are taken approximately weekly and are used in conjunction with Solinst non vented pressure transducers collocated with Solinst Barologgers installed in stilling wells to manufacture a stage-discharge relationship curve. Our most reliable method of collecting manual discharge measurements has proven to be the salt conductivity sudden-injection method described in Hongve, 1987. In the past manual measurement methods have been obtained using the velocity area method utilizing different methods for obtaining velocity including pygmy and velocity head rods.
Sensor ID and descriptions-
BT_SW_0_ManDis, Discharge
Subject Keywords
Coverage
Spatial
Temporal
Start Date: | |
---|---|
End Date: |
Content
ReadMe.md
BCCZO -- Streamflow / Discharge -- Manual (BT_SW_0_ManDis) -- Betasso -- (2013-2017)
OVERVIEW
Description/Abstract
Manual discharge measurements at the Boulder Creek CZO are taken approximately weekly and are used in conjunction with Solinst non vented pressure transducers collocated with Solinst Barologgers installed in stilling wells to manufacture a stage-discharge relationship curve. Our most reliable method of collecting manual discharge measurements has proven to be the salt conductivity sudden-injection method described in Hongve, 1987. In the past manual measurement methods have been obtained using the velocity area method utilizing different methods for obtaining velocity including pygmy and velocity head rods.
Query page here: https://bcczo.colorado.edu/query/bt-sw-0-mandis.shtml
Sensor ID and descriptions- BT_SW_0_ManDis, Discharge
Creator/Author
Suzanne Anderson|Dillon Ragar
CZOs
Boulder
Contact
bcczodata@colorado.edu
Subtitle
Manual discharge calculated at stream gauge Group ID: BT_SW_0_ManDis
SUBJECTS
Disciplines
Hydrology
Topics
Streamflow / Discharge
Subtopic
Manual (BT_SW_0_ManDis)
Keywords
manual|discharge|hydrology|Betasso
Variables
Date Time|Site ID|Method|Q (m^3/s)
Variables ODM2
Discharge
TEMPORAL
Date Start
2013-10-08
Date End
2017-09-26
SPATIAL
Field Areas
Betasso
Location
Betasso
North latitude
40.012802
South latitude
40.007137
West longitude
-105.340425
East longitude
-105.334322
REFERENCE
CZO ID
3969
Related datasets
BCCZO -- Surface Water Chemistry -- (BT_SW_0) -- Betasso -- (2008-2017)
Additional Metadata
Name | Value |
---|---|
czos | Boulder |
czo_id | 3969 |
keywords | manual, discharge, hydrology, Betasso |
subtitle | Manual discharge calculated at stream gauge Group ID: BT_SW_0_ManDis |
variables | Date Time, Site ID, Method, Q (m^3/s) |
disciplines | Hydrology |
related_datasets | 3064 |
related_datasets_hs | https://www.hydroshare.org/resource/3aa9c239e24f44a68469a2c34b88eced/ |
How to Cite
This resource is shared under the Creative Commons Attribution CC BY.
http://creativecommons.org/licenses/by/4.0/
Comments
There are currently no comments
New Comment