Checking for non-preferred file/folder path names (may take a long time depending on the number of files/folders) ...
This resource contains some files/folders that have non-preferred characters in their name. Show non-conforming files/folders.
This resource contains content types with files that need to be updated to match with metadata changes. Show content type files that need updating.
Authors: |
|
|
---|---|---|
Owners: |
|
This resource does not have an owner who is an active HydroShare user. Contact CUAHSI (help@cuahsi.org) for information on this resource. |
Type: | Resource | |
Storage: | The size of this resource is 1.2 MB | |
Created: | May 12, 2022 at 6:38 p.m. | |
Last updated: | May 12, 2022 at 8:45 p.m. | |
Citation: | See how to cite this resource |
Sharing Status: | Public |
---|---|
Views: | 791 |
Downloads: | 11 |
+1 Votes: | Be the first one to this. |
Comments: | No comments (yet) |
Abstract
Hydrogeophysical data for characterization of the Moorpark Reclamation Facility in Moorpark, CA. This facility is located along the Arroyo Las Posas River in the Little Simi Valley. The facility contains about 32 percolation ponds of which six ponds were selected to be evaluated in this study. The acquired data includes Electrical Resistivity Tomography, Electromagnetic Induction, and Guelph permeameter measurements. This data set is discussed in detail in Uhlemann et al., 3D Hydrogeophysical Characterization of Managed Aquifer Recharge Basins.
Subject Keywords
Coverage
Spatial
Content
readme.txt
Hydrogeophysical data for characterization of the Moorpark Reclamation Facility in Moorpark, CA. This data set includes ERT, EMI, and hydraulic conductivity measurements in support of characterizing the Moorpark Reclamation Facility, in Moorpark, CA, USA. The data set is structured in 3 folder, with each folder representing the data acquired with each technique. EM: Measured apparent conductivities using a CMD Mini Explorer (GF Instruments). The data has been filtered, and points within a 0.5 m radius have been averaged. No other processing has been applied. Data is provided in a text file, with coordinates for each sounding. The coordinate system is NAD83 UTM Zone 3N. The header provides information on the system settings. Data were acquired using a horizontal coplanar loop orientation, at 24740 Hz, at 0.2, 0.33, 0.5, 0.72, 1.03, and 1.50 m coil separation. The system was carried about 0.1 m above the ground. ERT: Data files for each pond, i.e. POND9, POND10, POND11. Each file contains the electrode arrangements with their measured transfer resistances Information on the electrodes location is provided at the top of the file Permeameter: The folder includes: (1) an excel sheet with the observations of the infiltration rate for each location, as well as the coordinates for each measurement (2) a jupyter notebook that reads the data and calculates the hydraulic conductivity from the observations
Credits
Funding Agencies
This resource was created using funding from the following sources:
Agency Name | Award Title | Award Number |
---|---|---|
Metropolitan Water District | Southern California’s Future Supply Actions Funding Program | 188682 |
How to Cite
This resource is shared under the Creative Commons Attribution-NoDerivs CC BY-ND.
http://creativecommons.org/licenses/by-nd/4.0/
Comments
There are currently no comments
New Comment