Checking for non-preferred file/folder path names (may take a long time depending on the number of files/folders) ...
This resource contains some files/folders that have non-preferred characters in their name. Show non-conforming files/folders.
This resource contains content types with files that need to be updated to match with metadata changes. Show content type files that need updating.
Alongshore variability over the inner continental shelf observed using fiber-optic distributed temperature sensing
Authors: |
|
|
---|---|---|
Owners: |
|
This resource does not have an owner who is an active HydroShare user. Contact CUAHSI (help@cuahsi.org) for information on this resource. |
Type: | Resource | |
Storage: | The size of this resource is 11.0 KB | |
Created: | Nov 30, 2017 at 8:53 p.m. | |
Last updated: | Apr 09, 2018 at 8:58 p.m. | |
Citation: | See how to cite this resource | |
Content types: | Single File Content |
Sharing Status: | Public |
---|---|
Views: | 1976 |
Downloads: | 48 |
+1 Votes: | Be the first one to this. |
Comments: | No comments (yet) |
Abstract
Circulation patterns over the inner continental shelf are spatially complex and highly variable in time. Significant fluxes of water, heat and other tracers may be associated with alongshore variability, especially in regions where the coastline and isobaths are not straight. Under stratified conditions, sustained subsurface observations are needed to characterize three-dimensional patterns of circulation, even in shallow water. To observe multiple scales of alongshore variability, a distributed temperature sensing system (DTS) was deployed within a larger-scale mooring array south of Martha's Vineyard, MA. A fiber-optic cable oriented in the alongshore direction was used to collect bottom temperature measurements with 5 m horizontal resolution, over a distance of 4.9 km. Although temperature gradients are generally stronger in the cross-shelf direction, significant variability is observed in the along-shelf direction. Along the 15 m isobath, rapid cooling events are observed with greater regularity and magnitude at locations closer to irregular bathymetry. The DTS observations show that fronts travel away from this region of strong tidal and bathymetric variability with an alongshore component. Lack of uniformity in magnitude and frequency of cooling events, at sites separated by less than 5 km in the alongshore direction, indicates that alongshore differences are present at short time scales of less than a day. Thus, the characteristics of high-frequency temperature variability at one location are therefore not necessarily representative of other nearby locations along the same isobath.
Raw project data is available by contacting ctemps@unr.edu
Subject Keywords
Coverage
Spatial
Temporal
Start Date: | |
---|---|
End Date: |
Content
How to Cite
This resource is shared under the Creative Commons Attribution CC BY.
http://creativecommons.org/licenses/by/4.0/
Comments
There are currently no comments
New Comment