Checking for non-preferred file/folder path names (may take a long time depending on the number of files/folders) ...
This resource contains some files/folders that have non-preferred characters in their name. Show non-conforming files/folders.
This resource contains content types with files that need to be updated to match with metadata changes. Show content type files that need updating.
3D electrical resistivity survey for reduction of groundwater drilling uncertainties in a clay rich environment
Authors: |
|
|
---|---|---|
Owners: |
|
This resource does not have an owner who is an active HydroShare user. Contact CUAHSI (help@cuahsi.org) for information on this resource. |
Type: | Resource | |
Storage: | The size of this resource is 655.4 KB | |
Created: | Jun 05, 2023 at 10:36 p.m. | |
Last updated: | Jun 08, 2023 at 6:22 p.m. | |
Citation: | See how to cite this resource |
Sharing Status: | Public |
---|---|
Views: | 467 |
Downloads: | 21 |
+1 Votes: | Be the first one to this. |
Comments: | No comments (yet) |
Abstract
Drilling for groundwater is expensive and challenging. It is even more challenging to find a location that will result in a high yield well in heterogenous environments. To tackle the heterogeneity issue, geophysical surveys can help to map the subsurface structure and help delineate the trajectory of drilling. This study displays the effectiveness of 3D Electrical Resistive Tomography (ERT) to locate permeable groundwater zone within a highly heterogenous subsurface. Ground truthing the acquired geophysical data with in-situ sampling helps to ensure accuracy in classifying groundwater zones in the final inverted 3D dataset while also delineating boundaries between permeable groundwater zones and clayey structures (from well data). In-situ sampling includes groundwater and soil sampling, where laboratory testing of both samples allows for this correlation. Clay zones in the dataset are classified from the nearby well data at similar depth range and from very low resistivity values after ERT data processing and laboratory measurements. The results display highly differentiating resistivity zones that are attributed to the scattered clay lenses (low resistivity) in conjunction with the freshwater zone (high resistivity). The distinction between clay and groundwater bodies is important to better inform drilling location for optimal groundwater yield. This study concludes that with the aid of low-cost geophysical surveys, and minimal in-situ sampling data correlations, groundwater boundaries and clay lens volumes can be identified easily.
Subject Keywords
Content
How to Cite
This resource is shared under the Creative Commons Attribution CC BY.
http://creativecommons.org/licenses/by/4.0/
Comments
There are currently no comments
New Comment