Checking for non-preferred file/folder path names (may take a long time depending on the number of files/folders) ...
This resource contains some files/folders that have non-preferred characters in their name. Show non-conforming files/folders.
This resource contains content types with files that need to be updated to match with metadata changes. Show content type files that need updating.
| Authors: |
|
|
|---|---|---|
| Owners: |
|
This resource does not have an owner who is an active HydroShare user. Contact CUAHSI (help@cuahsi.org) for information on this resource. |
| Type: | Resource | |
| Storage: | The size of this resource is 216.6 KB | |
| Created: | Sep 03, 2025 at 7:23 p.m. (UTC) | |
| Last updated: | Apr 04, 2026 at 1:48 a.m. (UTC) (Metadata update) | |
| Published date: | Apr 04, 2026 at 1:48 a.m. (UTC) | |
| DOI: | 10.4211/hs.e025fb27b18141beab4cebda71528efc | |
| Citation: | See how to cite this resource |
| Sharing Status: | Published |
|---|---|
| Views: | 92 |
| Downloads: | 3 |
| +1 Votes: | Be the first one to this. |
| Comments: | No comments (yet) |
Abstract
This study was conducted in the Paint Rock research watershed (outlet location: 34.96861724, -86.16501705) on privately owned property in Jackson County (AL, USA). The watershed drains a non-perennial unnamed tributary to Burks Creek, and contains 2.97 km^2 of deciduous forest in the Cumberland Plateau physiographic section. Located near Estillfork, AL, the watershed spans an elevation range from 211 to 550 m above sea level, and is a tributary to the Paint Rock River (within the larger Tennessee basin). The region has a humid subtropical climate, with mean daily January and July air temperatures of 4.4°C and 25.4°C respectively, and mean annual precipitation of 1,390 mm/yr.
Samples were filtered with a 0.45um PES filter and frozen until analysis. Aqueous concentrations of anions were determined using an IC-3000 IC system (Dionex, Sunnyvale, CA) equipped with Dionex AERS 500 suppressor (2 mm, Thermo Scientific) and Dionex AS auto-sampler (Thermo Scientific). A Dionex IonPac AS15 column (2 mm × 50 mm, Thermo Scientific) with a guard column Dionex IonPac AG15 (2 mm × 50 mm, Thermo Scientific) was used to separate anions using a mobile phase of 38 mM KOH and a flow rate of 0.3 mL/min. The column temperature is 30 °C. Chromeleon software 7.1 is used for system control. Final data tab shows average of triplicates collected in the field and st dev of triplicates. Any NO3 values below 0.01 mg/L are below the lowest standard used in lab analysis and should be interpreted with caution.
Subject Keywords
Coverage
Temporal
| Start Date: | |
|---|---|
| End Date: |
Content
Related Resources
| The content of this resource references | https://www.hydroshare.org/resource/ac0c4f31e8a64c52bae41e5719bd3c14/ |
| This resource is described by | https://www.hydroshare.org/resource/656211b1a1484433a3bc524fb968b4bd/ |
Credits
Funding Agencies
This resource was created using funding from the following sources:
| Agency Name | Award Title | Award Number |
|---|---|---|
| U.S. National Science Foundation | Aquatic Intermittency Effects of Microbiomes on Streams | 2019603 |
How to Cite
This resource is shared under the Creative Commons Attribution CC BY.
http://creativecommons.org/licenses/by/4.0/
Comments
There are currently no comments
New Comment